Where this text comes from
- Citation
- 40 CFR Part 63, Subpart CCCCCC
- Official title
- Subpart CCCCCC—National Emission Standards for Hazardous Air Pollutants for Source Category: Gasoline Dispensing Facilities
- Text as of
- eCFR current through 2026-10-28, retrieved 2026-10-30
- Latest amendment
- 2021-01-18
- Source note
- 73 FR 1945, Jan. 10, 2008, unless otherwise noted.
Headings and quoted sections on this page are copied from the eCFR text of Subpart CCCCCC without changes. AirPermitHub checks eCFR every week and reviews any change before publishing it, so this page can trail eCFR by a few days. eCFR is maintained by the Office of the Federal Register and the Government Publishing Office. It is not an official legal edition of the CFR, and it does not show how an agency has applied the rule in a permit.
Where to look in Subpart CCCCCC
Sections sorted by the words in their eCFR headings. Read the full section before relying on it; requirements often sit in more than one place.
- Who is covered
- § 63.11110§ 63.11111§ 63.11112
- Compliance dates
- § 63.11113
- Showing compliance
- § 63.11113
- Monitoring
- § 63.11120
- Tests, methods, and calculations
- § 63.11120
- Notifications, reports, records
- § 63.11124§ 63.11125§ 63.11126
- Definitions
- § 63.11132
- Who implements it
- § 63.11131
- General provisions
- § 63.11130
Who the subpart covers, in the rule's own words
The sections that set out what the subpart applies to, quoted in full from eCFR. Dates, sizes, and other figures are the rule's, not AirPermitHub's.
§ 63.11110 What is the purpose of this subpart?
Open in eCFRThis subpart establishes national emission limitations and management practices for hazardous air pollutants (HAP) emitted from the loading of gasoline storage tanks at gasoline dispensing facilities (GDF). This subpart also establishes requirements to demonstrate compliance with the emission limitations and management practices.
§ 63.11111 Am I subject to the requirements in this subpart?
Open in eCFR(a) The affected source to which this subpart applies is each GDF that is located at an area source. The affected source includes each gasoline cargo tank during the delivery of product to a GDF and also includes each storage tank.
(b) If your GDF has a monthly throughput of less than 10,000 gallons of gasoline, you must comply with the requirements in § 63.11116.
(c) If your GDF has a monthly throughput of 10,000 gallons of gasoline or more, you must comply with the requirements in § 63.11117.
(d) If your GDF has a monthly throughput of 100,000 gallons of gasoline or more, you must comply with the requirements in § 63.11118.
(e) An affected source shall, upon request by the Administrator, demonstrate that their monthly throughput is less than the 10,000-gallon or the 100,000-gallon threshold level, as applicable. For new or reconstructed affected sources, as specified in § 63.11112(b) and (c), recordkeeping to document monthly throughput must begin upon startup of the affected source. For existing sources, as specified in § 63.11112(d), recordkeeping to document monthly throughput must begin on January 10, 2008. For existing sources that are subject to this subpart only because they load gasoline into fuel tanks other than those in motor vehicles, as defined in § 63.11132, recordkeeping to document monthly throughput must begin on January 24, 2011. Records required under this paragraph shall be kept for a period of 5 years.
(f) If you are an owner or operator of affected sources, as defined in paragraph (a) of this section, you are not required to obtain a permit under 40 CFR part 70 or 40 CFR part 71 as a result of being subject to this subpart. However, you must still apply for and obtain a permit under 40 CFR part 70 or 40 CFR part 71 if you meet one or more of the applicability criteria found in 40 CFR 70.3(a) and (b) or 40 CFR 71.3(a) and (b).
(g) The loading of aviation gasoline into storage tanks at airports, and the subsequent transfer of aviation gasoline within the airport, is not subject to this subpart.
(h) Monthly throughput is the total volume of gasoline loaded into, or dispensed from, all the gasoline storage tanks located at a single affected GDF. If an area source has two or more GDF at separate locations within the area source, each GDF is treated as a separate affected source.
Show the rest of § 63.11111 (3 more paragraphs)Hide the rest of § 63.11111
(i) If your affected source's throughput ever exceeds an applicable throughput threshold, the affected source will remain subject to the requirements for sources above the threshold, even if the affected source throughput later falls below the applicable throughput threshold.
(j) The dispensing of gasoline from a fixed gasoline storage tank at a GDF into a portable gasoline tank for the on-site delivery and subsequent dispensing of the gasoline into the fuel tank of a motor vehicle or other gasoline-fueled engine or equipment used within the area source is only subject to § 63.11116 of this subpart.
(k) For any affected source subject to the provisions of this subpart and another Federal rule, you may elect to comply only with the more stringent provisions of the applicable subparts. You must consider all provisions of the rules, including monitoring, recordkeeping, and reporting. You must identify the affected source and provisions with which you will comply in your Notification of Compliance Status required under § 63.11124. You also must demonstrate in your Notification of Compliance Status that each provision with which you will comply is at least as stringent as the otherwise applicable requirements in this subpart. You are responsible for making accurate determinations concerning the more stringent provisions, and noncompliance with this rule is not excused if it is later determined that your determination was in error, and, as a result, you are violating this subpart. Compliance with this rule is your responsibility and the Notification of Compliance Status does not alter or affect that responsibility.
[73 FR 1945, Jan. 10, 2008, as amended at 76 FR 4181, Jan. 24, 2011]
Every section in Subpart CCCCCC
15 sections and 3 tables, in eCFR order. Each link opens the official text.
What This Subpart Covers
- § 63.11110What is the purpose of this subpart?Amended 2016-12-22
- § 63.11111Am I subject to the requirements in this subpart?Amended 2016-12-22
- § 63.11112What parts of my affected source does this subpart cover?Amended 2016-12-22
- § 63.11113When do I have to comply with this subpart?Amended 2016-12-22
Emission Limitations and Management Practices
- § 63.11115What are my general duties to minimize emissions?Amended 2016-12-22
- § 63.11116Requirements for facilities with monthly throughput of less than 10,000 gallons of gasoline.Amended 2016-12-22
- § 63.11117Requirements for facilities with monthly throughput of 10,000 gallons of gasoline or more.Amended 2016-12-22
- § 63.11118Requirements for facilities with monthly throughput of 100,000 gallons of gasoline or more.Amended 2016-12-22
Testing and Monitoring Requirements
- § 63.11120What testing and monitoring requirements must I meet?Amended 2016-12-22
Notifications, Records, and Reports
- § 63.11124What notifications must I submit and when?Amended 2021-01-18
- § 63.11125What are my recordkeeping requirements?Amended 2016-12-22
- § 63.11126What are my reporting requirements?Amended 2016-12-22
Other Requirements and Information
- § 63.11130What parts of the General Provisions apply to me?Amended 2016-12-22
- § 63.11131Who implements and enforces this subpart?Amended 2016-12-22
- § 63.11132What definitions apply to this subpart?Amended 2016-12-22
Tables and appendices
- TableTable 1 to Subpart CCCCCC of Part 63—Applicability Criteria and Management Practices for Gasoline Dispensing Facilities With Monthly Throughput of 100,000 Gallons of Gasoline or More ¹See eCFR
- TableTable 2 to Subpart CCCCCC of Part 63—Applicability Criteria and Management Practices for Gasoline Cargo Tanks Unloading at Gasoline Dispensing Facilities With Monthly Throughput of 100,000 Gallons of Gasoline or MoreSee eCFR
- TableTable 3 to Subpart CCCCCC of Part 63—Applicability of General ProvisionsSee eCFR
Amendment history
Dates on which eCFR records a change to any section of Subpart CCCCCC, newest first.
- 2021-01-18
- 2020-12-07
- 2020-11-19
- 2016-12-22
To read the rulemakings behind these dates, search the Federal Register for Subpart CCCCCC. New EPA air rules and proposals also appear in the Federal Air Rule Tracker.
AirPermitHub provides educational, engineering, research, and compliance-support information. Information provided by the platform does not constitute legal advice and should not replace review of applicable regulations, permits, agency guidance, or consultation with qualified professionals. Full disclaimer